Paths can be interrupted by insulation and blocking air paths. A material's insulation is governed by mass, stiffening and damping...more

Air Testing & Leakage
Air Pressure Testing is not just for new-builds, it can be used to find leakage areas in existing buildings, improve the air tightness and improve/stop drafts..more
Part L1B
Conservation of fuel and power in Existing Dwellings

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
How Many Properties Need An Air Tightness Test?
If you have 4 or less properties of the same type then only one test needs to be undertaken per type. If you have more than 4 but less than 40 dwellings of a type then you need at least two tests to be done on each type. Finally, if there are more than 40 properties of a particular type then at least 5% of each type needs to be tested UNLESS the first 5 get a passing score - then this can be dropped to just 2%.
Do I Need An Air Leakage Test?
Planning your test in advance will help our experience air assessment team covering the UK to determine how many tests you'll need ahead of time per property and will be happy to offer advice on the best ways to gain your air permeability rating.
Domestic properties and commercial buildings over a certain size must have a passing air leakage certificate before the property can be handed over following a sale. All new buildings in England and Wales have had this requirement since 2006 and in Scotland this has been mandatory since 2010.
Part L of the Government building regulations explains that on a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested.
What Air Permeability Rating Do I Need?
A passing score in the UK is 10 m³/(h.m²) for an air permeability rating which resembles the amount of uncontrolled air that's leaking from the dwelling. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.
What Does An Air Leakage Test Involve?
Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.
During an air test in the UK the pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.
There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.
When Should The Test Take Place?
For obvious reasons, an air pressure test is generally one of the last surveys to be undertaken once all the walls, windows, doors etc. are complete and sealed to stop any air escaping and prevent drafts through the property. The building envelope will also need to be completed.
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Air-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
Air Testing can also be known as:
Air Integrity Testing, Domestic Air Pressure Testing, Fan Pressure Testing, Air Leakage Testing, Domestic Air Testing, Air Pressure Testing, Domestic Air Integrity Testing, Domestic House Leakage Testing, Domestic Air Tightness Testing, Domestic Air Leakage Testing, Air Tightness Testing, Domestic Fan Pressure Testing, House Leakage Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In Area O
Domestic AIR Tests in Oadby, Domestic AIR Tests in Oakamoor, Domestic AIR Tests in Oakham, Domestic AIR Tests in Oban, Domestic AIR Tests in Ockham, Domestic AIR Tests in Oddingley, Domestic AIR Tests in Okehampton, Domestic AIR Tests in Old Warden, Domestic AIR Tests in Old Windsor, Domestic AIR Tests in Oldbury, Domestic AIR Tests in Oldham, Domestic AIR Tests in Oldmeldrum, Domestic AIR Tests in Olney, Domestic AIR Tests in Omagh, Domestic AIR Tests in Once Brewed, Domestic AIR Tests in Ongar, Domestic AIR Tests in Orford, Domestic AIR Tests in Orkney, Domestic AIR Tests in Ormskirk, Domestic AIR Tests in Orpington, Domestic AIR Tests in Ossett, Domestic AIR Tests in Oswaldtwistle, Domestic AIR Tests in Oswestry, Domestic AIR Tests in Otley, Domestic AIR Tests in Otley, Domestic AIR Tests in Ottery St. Mary, Domestic AIR Tests in Oulton, Domestic AIR Tests in Oundle, Domestic AIR Tests in Outwood, Domestic AIR Tests in Overbury, Domestic AIR Tests in Oxford, Domestic AIR Tests in Oxted, Domestic AIR Tests in Oxton,