Good Hearing?
A typical person with good hearing can hear from about 20Hz to 20kHz (the audio bandwidth). A person's voice will usually range from 500Hz to 2kHz...more

Air Testing & Leakage
We can offer additional services at discounted rates along side our tests! These are Sound Testing and Part F. Ask our Consultants for more
Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
When Should The Test Take Place?
The air leakage should be completed once the building is completed. All doors and windows in place, all skirting boards sealed, traps filled with water and any penetrations through the envelope of the building need to be sealed. Please find checklist within the downloads section of the website which provide a comprehensive list of requirements. People who follow this checklist have a much higher change of passing the air test first time.
What Air Permeability Rating Do I Need?
Your air permeability rating resembles the amount of uncontrolled air that's leaking from the dwelling. A passing score in the UK is 10 m³/(h.m²). If the air test fails, we will help you identify where these leakage areas occur in the hope that a passing rate will be achieved following a re-test. The final target will be set by the design SAP Calculation (please contact us if you require one of these in the UK )
How Many Properties Need An Air Tightness Test?
The number of tests required are as follows:
- 4 or less properties of the same type: one test needed per type
- More than 4 but less than 40 dwellings of a type: at least two tests of each type
- More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%
What Does An Air Leakage Test in the UK Involve?
Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.
There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.
Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.
Why E2 Consultants?
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.
At E2 Consultants we offer Air Testing throughout the UK and surrounding areas. Our experienced air testing consultants will also be happy to offer advice on the best ways to gain your target rating.
E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.
For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Air-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
Air Testing can also be known as:
Fan Pressure Testing, House Leakage Testing, Domestic Air Pressure Testing, Domestic Air Integrity Testing, Air Leakage Testing, Domestic Air Testing, Domestic House Leakage Testing, Air Tightness Testing, Domestic Fan Pressure Testing, Air Integrity Testing, Domestic Air Leakage Testing, Air Pressure Testing, Domestic Air Tightness Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In Area E
Domestic AIR Tightness Tests in Eaglescliffe, Domestic AIR Tightness Tests in Eakring, Domestic AIR Tightness Tests in Ealing, Domestic AIR Tightness Tests in Earls Colne, Domestic AIR Tightness Tests in Earls Court, Domestic AIR Tightness Tests in Earlston, Domestic AIR Tightness Tests in Earlswood, Domestic AIR Tightness Tests in Easington, Domestic AIR Tightness Tests in Easingwold, Domestic AIR Tightness Tests in East Bergholt, Domestic AIR Tightness Tests in East Dereham, Domestic AIR Tightness Tests in East Drayton, Domestic AIR Tightness Tests in East Dulwich, Domestic AIR Tightness Tests in East Finchley, Domestic AIR Tightness Tests in East Grinstead, Domestic AIR Tightness Tests in East Ham, Domestic AIR Tightness Tests in East Horsley, Domestic AIR Tightness Tests in East Kilbride, Domestic AIR Tightness Tests in East Peckham, Domestic AIR Tightness Tests in East Preston, Domestic AIR Tightness Tests in Eastbourne, Domestic AIR Tightness Tests in Eastcott, Domestic AIR Tightness Tests in Eastham, Domestic AIR Tightness Tests in Eastleigh, Domestic AIR Tightness Tests in Easton, Domestic AIR Tightness Tests in Eastville, Domestic AIR Tightness Tests in Eastwood, Domestic AIR Tightness Tests in Ebbw Vale, Domestic AIR Tightness Tests in Eccles, Domestic AIR Tightness Tests in Eccleshall, Domestic AIR Tightness Tests in Eccleston, Domestic AIR Tightness Tests in Edenbridge, Domestic AIR Tightness Tests in Edgeware, Domestic AIR Tightness Tests in Edinburgh, Domestic AIR Tightness Tests in Edingley, Domestic AIR Tightness Tests in Edmonton, Domestic AIR Tightness Tests in Effingham, Domestic AIR Tightness Tests in Egham, Domestic AIR Tightness Tests in Eglinton, Domestic AIR Tightness Tests in Egremont, Domestic AIR Tightness Tests in Eldersfield, Domestic AIR Tightness Tests in Elgin, Domestic AIR Tightness Tests in Elland, Domestic AIR Tightness Tests in Ellesmere, Domestic AIR Tightness Tests in Ellesmere Port, Domestic AIR Tightness Tests in Ellon, Domestic AIR Tightness Tests in Elmhurst, Domestic AIR Tightness Tests in Elstead, Domestic AIR Tightness Tests in Elston, Domestic AIR Tightness Tests in Eltham, Domestic AIR Tightness Tests in Ely, Domestic AIR Tightness Tests in Emsworth, Domestic AIR Tightness Tests in Enfield, Domestic AIR Tightness Tests in Enford, Domestic AIR Tightness Tests in England, Domestic AIR Tightness Tests in Enniskillen, Domestic AIR Tightness Tests in Epping, Domestic AIR Tightness Tests in Epsom, Domestic AIR Tightness Tests in Erith, Domestic AIR Tightness Tests in Erskine, Domestic AIR Tightness Tests in Esher, Domestic AIR Tightness Tests in Essington, Domestic AIR Tightness Tests in Eton, Domestic AIR Tightness Tests in Everton, Domestic AIR Tightness Tests in Evesham, Domestic AIR Tightness Tests in Ewell, Domestic AIR Tightness Tests in Exeter, Domestic AIR Tightness Tests in Exford, Domestic AIR Tightness Tests in Exmouth, Domestic AIR Tightness Tests in Eye, Domestic AIR Tightness Tests in Eyemouth, Domestic AIR Tightness Tests in Eynsford,