Offices Nationwide

Air Testing & Leakage
We have a checklist you can download for Air Leakage Testing. If you follow our air tightness checklist, this will improve your likelihood to achieve a pass!

Sound Transmissions
Paths can be interrupted by insulation and blocking air paths. A material's insulation is governed by mass, stiffening and damping...more
Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
How Many Properties Need An Air Tightness Test?
If you have 4 or less properties of the same type then only one test needs to be undertaken per type. If you have more than 4 but less than 40 dwellings of a type then you need at least two tests to be done on each type. Finally, if there are more than 40 properties of a particular type then at least 5% of each type needs to be tested UNLESS the first 5 get a passing score - then this can be dropped to just 2%.
What Air Permeability Rating Do I Need?
A passing score in the UK is 10 m³/(h.m²) for an air permeability rating which resembles the amount of uncontrolled air that's leaking from the dwelling. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.
When Should The Test Take Place?
A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.
What Does An Air Leakage Test Involve?
Employees can still do their job inside a commercial building in the UK, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building. There should be no outside access once the test has begun - which lasts for approximately 90 minutes, so plan accordingly.
An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results. Please note: an air test cannot be carried out if wind speed is more than 13mph. 3 metres per second is the ideal wind speed when undertaking an air test in the UK.
During an air test in the UK the pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.
Do I Need An Air Leakage Test?
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, over a certain size, must have a passing air leakage certificate before the property can be sold.
Part L of the Government building regulations explains that on a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested.
Planning your test in advance will help our experience air assessment team covering the UK to determine how many tests you'll need ahead of time per property and will be happy to offer advice on the best ways to gain your air permeability rating.
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Air-Leakage-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
Air Leakage Testing can also be known as:
Domestic Air Testing, Air Integrity Testing, House Leakage Testing, Fan Pressure Testing, Domestic Fan Pressure Testing, Domestic Air Tightness Testing, Domestic Air Integrity Testing, Domestic House Leakage Testing, Air Pressure Testing, Domestic Air Pressure Testing, Air Tightness Testing, Air Testing, Domestic Air Leakage Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In Area O
Domestic Air pressure testing in Oadby, Domestic Air pressure testing in Oakamoor, Domestic Air pressure testing in Oakham, Domestic Air pressure testing in Oban, Domestic Air pressure testing in Ockham, Domestic Air pressure testing in Oddingley, Domestic Air pressure testing in Okehampton, Domestic Air pressure testing in Old Warden, Domestic Air pressure testing in Old Windsor, Domestic Air pressure testing in Oldbury, Domestic Air pressure testing in Oldham, Domestic Air pressure testing in Oldmeldrum, Domestic Air pressure testing in Olney, Domestic Air pressure testing in Omagh, Domestic Air pressure testing in Once Brewed, Domestic Air pressure testing in Ongar, Domestic Air pressure testing in Orford, Domestic Air pressure testing in Orkney, Domestic Air pressure testing in Ormskirk, Domestic Air pressure testing in Orpington, Domestic Air pressure testing in Ossett, Domestic Air pressure testing in Oswaldtwistle, Domestic Air pressure testing in Oswestry, Domestic Air pressure testing in Otley, Domestic Air pressure testing in Otley, Domestic Air pressure testing in Ottery St. Mary, Domestic Air pressure testing in Oulton, Domestic Air pressure testing in Oundle, Domestic Air pressure testing in Outwood, Domestic Air pressure testing in Overbury, Domestic Air pressure testing in Oxford, Domestic Air pressure testing in Oxted, Domestic Air pressure testing in Oxton,