Offices Nationwide

Environmental Noise Levels
The max exposure time at 85 dBA is 8 hours, at 110 dBA it's just 1 min 29 seconds. If exposed, limit the time and wear hearing protection...more

The Decibel Scale
Gives an approx of human perception of loudness. This is because the human ear has a logarithmic response to changes in sound level...more
Thermal Bridging And Airtightness
Enhanced Construction Details

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
What Air Permeability Rating Do I Need?
The air tightness rating of a property is not a fixed figure. This is set by the design SAP Calculation carried out (please contact us if you also require a SAP Calculation in the UK ). However the worst acceptable standard for air tightness is 10 m³/(h.m²) which resembles the amount of uncontrolled air that's leaking from the dwelling. However this does not mean that it would pass the SAP Calculations Design Air Permeability standard. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.
What Does An Air Leakage Test in the UK Involve?
Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.
Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.
There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.
How Many Properties Need An Air Tightness Test?
According to Part L1a, an air pressure test needs to be undertaken on 50% of all dwelling types or three units of each type depending on which value is smaller. A block of flats is considered as a separate development and should be treated as such no matter on the number of blocks on the site. Furthermore, the testing should be done on the first batch of each type of dwelling to be completed. The need to test multiple versions of each type is to confirm the design and construction procedures are up to code according to Government regulations.
Why E2 Consultants?
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.
E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.
For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk
At E2 Consultants we offer Air Testing throughout the UK and surrounding areas. Our experienced air testing consultants will also be happy to offer advice on the best ways to gain your target rating.
When Should The Test Take Place?
The air leakage should be completed once the building is completed. All doors and windows in place, all skirting boards sealed, traps filled with water and any penetrations through the envelope of the building need to be sealed. Please find checklist within the downloads section of the website which provide a comprehensive list of requirements. People who follow this checklist have a much higher change of passing the air test first time.
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Air-Leakage-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
Air Leakage Testing can also be known as:
Domestic Air Leakage Testing, Domestic Air Testing, Domestic House Leakage Testing, Air Tightness Testing, Fan Pressure Testing, Domestic Air Pressure Testing, Domestic Air Integrity Testing, House Leakage Testing, Domestic Fan Pressure Testing, Air Integrity Testing, Air Pressure Testing, Air Testing, Domestic Air Tightness Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In Area E
Domestic Air tests in Eaglescliffe, Domestic Air tests in Eakring, Domestic Air tests in Ealing, Domestic Air tests in Earls Colne, Domestic Air tests in Earls Court, Domestic Air tests in Earlston, Domestic Air tests in Earlswood, Domestic Air tests in Easington, Domestic Air tests in Easingwold, Domestic Air tests in East Bergholt, Domestic Air tests in East Dereham, Domestic Air tests in East Drayton, Domestic Air tests in East Dulwich, Domestic Air tests in East Finchley, Domestic Air tests in East Grinstead, Domestic Air tests in East Ham, Domestic Air tests in East Horsley, Domestic Air tests in East Kilbride, Domestic Air tests in East Peckham, Domestic Air tests in East Preston, Domestic Air tests in Eastbourne, Domestic Air tests in Eastcott, Domestic Air tests in Eastham, Domestic Air tests in Eastleigh, Domestic Air tests in Easton, Domestic Air tests in Eastville, Domestic Air tests in Eastwood, Domestic Air tests in Ebbw Vale, Domestic Air tests in Eccles, Domestic Air tests in Eccleshall, Domestic Air tests in Eccleston, Domestic Air tests in Edenbridge, Domestic Air tests in Edgeware, Domestic Air tests in Edinburgh, Domestic Air tests in Edingley, Domestic Air tests in Edmonton, Domestic Air tests in Effingham, Domestic Air tests in Egham, Domestic Air tests in Eglinton, Domestic Air tests in Egremont, Domestic Air tests in Eldersfield, Domestic Air tests in Elgin, Domestic Air tests in Elland, Domestic Air tests in Ellesmere, Domestic Air tests in Ellesmere Port, Domestic Air tests in Ellon, Domestic Air tests in Elmhurst, Domestic Air tests in Elstead, Domestic Air tests in Elston, Domestic Air tests in Eltham, Domestic Air tests in Ely, Domestic Air tests in Emsworth, Domestic Air tests in Enfield, Domestic Air tests in Enford, Domestic Air tests in England, Domestic Air tests in Enniskillen, Domestic Air tests in Epping, Domestic Air tests in Epsom, Domestic Air tests in Erith, Domestic Air tests in Erskine, Domestic Air tests in Esher, Domestic Air tests in Essington, Domestic Air tests in Eton, Domestic Air tests in Everton, Domestic Air tests in Evesham, Domestic Air tests in Ewell, Domestic Air tests in Exeter, Domestic Air tests in Exford, Domestic Air tests in Exmouth, Domestic Air tests in Eye, Domestic Air tests in Eyemouth, Domestic Air tests in Eynsford,