Offices Nationwide

The Decibel Scale
Gives an approx of human perception of loudness. This is because the human ear has a logarithmic response to changes in sound level...more

Reverberation Time
The reverberation time of a room is defined as the time it takes for sound to decay by 60 dB after an abrupt termination...more
Part L1B
Conservation of fuel and power in Existing Dwellings

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
Why E2 Consultants?
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.
At E2 Consultants we offer Air Pressure Testing throughout the UK and surrounding areas. Our experienced air pressure testing consultants will also be happy to offer advice on the best ways to gain your target rating.
For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk
E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.
How Many Properties Need An Air Tightness Test?
If you have 4 or less properties of the same type then only one test needs to be undertaken per type. If you have more than 4 but less than 40 dwellings of a type then you need at least two tests to be done on each type. Finally, if there are more than 40 properties of a particular type then at least 5% of each type needs to be tested UNLESS the first 5 get a passing score - then this can be dropped to just 2%.
When Should The Test Take Place?
The air leakage should be completed once the building is completed. All doors and windows in place, all skirting boards sealed, traps filled with water and any penetrations through the envelope of the building need to be sealed. Please find checklist within the downloads section of the website which provide a comprehensive list of requirements. People who follow this checklist have a much higher change of passing the air test first time.
What Air Permeability Rating Do I Need?
The air tightness rating of a property is not a fixed figure. This is set by the design SAP Calculation carried out (please contact us if you also require a SAP Calculation in the UK ). However the worst acceptable standard for air tightness is 10 m³/(h.m²) which resembles the amount of uncontrolled air that's leaking from the dwelling. However this does not mean that it would pass the SAP Calculations Design Air Permeability standard. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.
What Does An Air Leakage Test in the UK Involve?
There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.
Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.
An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results. Please note: an air test cannot be carried out if wind speed is more than 13mph. 3 metres per second is the ideal wind speed when undertaking an air test in the UK.
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Domestic-Air-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
Domestic Air Testing can also be known as:
Domestic House Leakage Testing, Domestic Air Integrity Testing, Domestic Air Tightness Testing, Air Leakage Testing, Air Testing, Domestic Fan Pressure Testing, Domestic Air Pressure Testing, Fan Pressure Testing, Air Tightness Testing, Air Integrity Testing, Domestic Air Leakage Testing, House Leakage Testing, Air Pressure Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In Area O
Domestic Air leakage testing in Oadby, Domestic Air leakage testing in Oakamoor, Domestic Air leakage testing in Oakham, Domestic Air leakage testing in Oban, Domestic Air leakage testing in Ockham, Domestic Air leakage testing in Oddingley, Domestic Air leakage testing in Okehampton, Domestic Air leakage testing in Old Warden, Domestic Air leakage testing in Old Windsor, Domestic Air leakage testing in Oldbury, Domestic Air leakage testing in Oldham, Domestic Air leakage testing in Oldmeldrum, Domestic Air leakage testing in Olney, Domestic Air leakage testing in Omagh, Domestic Air leakage testing in Once Brewed, Domestic Air leakage testing in Ongar, Domestic Air leakage testing in Orford, Domestic Air leakage testing in Orkney, Domestic Air leakage testing in Ormskirk, Domestic Air leakage testing in Orpington, Domestic Air leakage testing in Ossett, Domestic Air leakage testing in Oswaldtwistle, Domestic Air leakage testing in Oswestry, Domestic Air leakage testing in Otley, Domestic Air leakage testing in Otley, Domestic Air leakage testing in Ottery St. Mary, Domestic Air leakage testing in Oulton, Domestic Air leakage testing in Oundle, Domestic Air leakage testing in Outwood, Domestic Air leakage testing in Overbury, Domestic Air leakage testing in Oxford, Domestic Air leakage testing in Oxted, Domestic Air leakage testing in Oxton,