Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.

Air Leaking Testing Across the UK

How Many Properties Need An Air Tightness Test?

The number of tests required are as follows:

  • 4 or less properties of the same type: one test needed per type
  • More than 4 but less than 40 dwellings of a type: at least two tests of each type
  • More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%

What Air Permeability Rating Do I Need?

The air tightness rating of a property is not a fixed figure. This is set by the design SAP Calculation carried out (please contact us if you also require a SAP Calculation in the UK ). However the worst acceptable standard for air tightness is 10 m³/(h.m²) which resembles the amount of uncontrolled air that's leaking from the dwelling. However this does not mean that it would pass the SAP Calculations Design Air Permeability standard. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.

What Does An Air Leakage Test in the UK Involve?

During an air test in the UK the pressure of the building will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.

Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.

There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.

When Should The Test Take Place?

The air leakage should be completed once the building is completed. All doors and windows in place, all skirting boards sealed, traps filled with water and any penetrations through the envelope of the building need to be sealed. Please find checklist within the downloads section of the website which provide a comprehensive list of requirements. People who follow this checklist have a much higher change of passing the air test first time.

Why E2 Consultants?

E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.

For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk

At E2 Consultants we offer Air Testing throughout the UK and surrounding areas. Our experienced air testing consultants will also be happy to offer advice on the best ways to gain your target rating.

For further House-Leakage-Testing information for your area, be sure to check out Air-Testing-.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100

» » »
House Leakage Testing
» Domestic Services » House Leakage Testing

In Area N

Domestic Air tests in Nailsea, Domestic Air tests in Nailsworth, Domestic Air tests in Nairn, Domestic Air tests in Nantwich, Domestic Air tests in Narberth, Domestic Air tests in Nayland, Domestic Air tests in Neath, Domestic Air tests in Needham Market, Domestic Air tests in Nelson, Domestic Air tests in Neston, Domestic Air tests in Netherton, Domestic Air tests in New Mills, Domestic Air tests in New Milton, Domestic Air tests in New Romney, Domestic Air tests in New Southgate, Domestic Air tests in Newark, Domestic Air tests in Newbury, Domestic Air tests in Newcastle, Domestic Air tests in Newcastle Emlyn, Domestic Air tests in Newcastle upon Tyne, Domestic Air tests in Newchapel, Domestic Air tests in Newcross, Domestic Air tests in Newent, Domestic Air tests in Newhaven, Domestic Air tests in Newlyn, Domestic Air tests in Newmarket, Domestic Air tests in Newnham, Domestic Air tests in Newport, Domestic Air tests in Newport, Domestic Air tests in Newport, Domestic Air tests in Newport on Tay, Domestic Air tests in Newport Pagnell, Domestic Air tests in Newquay, Domestic Air tests in Newry, Domestic Air tests in Newton, Domestic Air tests in Newton Abbot, Domestic Air tests in Newton Aycliffe, Domestic Air tests in Newton le Willows, Domestic Air tests in Newton Stewart, Domestic Air tests in Newtown, Domestic Air tests in Newtownabbey, Domestic Air tests in Newtownards, Domestic Air tests in Normanton, Domestic Air tests in North Berwick, Domestic Air tests in North East, Domestic Air tests in North Finchley, Domestic Air tests in North Kenningston, Domestic Air tests in North Walsham, Domestic Air tests in Northallerton, Domestic Air tests in Northampton, Domestic Air tests in Northern Ireland, Domestic Air tests in Northleach, Domestic Air tests in Northolt, Domestic Air tests in Northwich, Domestic Air tests in Norton, Domestic Air tests in Norwich, Domestic Air tests in Norwood, Domestic Air tests in Nottingham, Domestic Air tests in Nottinghill, Domestic Air tests in Nuneaton, Domestic Air tests in Nutfield,