Our engineers use Thermal camera and extensive knowledge of buildings to help find leakage areas within the building and can advice of these.

How loud is too loud?
Noise above 85 dBA over time will cause hearing loss. In general, the louder the noise, the less time required before hearing loss...more
Part F
Means of Ventilation

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
How Many Properties Need An Air Tightness Test?
The number of tests required are as follows:
- 4 or less properties of the same type: one test needed per type
- More than 4 but less than 40 dwellings of a type: at least two tests of each type
- More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%
When Should The Test Take Place?
For obvious reasons, an air pressure test is generally one of the last surveys to be undertaken once all the walls, windows, doors etc. are complete and sealed to stop any air escaping and prevent drafts through the property. The building envelope will also need to be completed.
What Does An Air Leakage Test Involve?
Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.
Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.
There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.
Do I Need An Air Leakage Test?
Part L of the Government building regulations explains that on a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested.
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, over a certain size, must have a passing air leakage certificate before the property can be sold.
We offer air leakage testing throughout the UK where our experienced assessors will be happy to offer advice on the best ways to gain your air permeability rating. Planning your test in advance will help us determine how many tests you'll need ahead of time per property.
What Air Permeability Rating Do I Need?
Your air permeability rating resembles the amount of uncontrolled air that's leaking from the dwelling. A passing score in the UK is 10 m³/(h.m²). If the air test fails, we will help you identify where these leakage areas occur in the hope that a passing rate will be achieved following a re-test.
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Domestic-Air-Tightness-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
Domestic Air Tightness Testing can also be known as:
Air Pressure Testing, Air Integrity Testing, Domestic Air Leakage Testing, Domestic Air Pressure Testing, Fan Pressure Testing, House Leakage Testing, Domestic Fan Pressure Testing, Air Leakage Testing, Air Tightness Testing, Domestic Air Testing, Domestic Air Integrity Testing, Domestic House Leakage Testing, Air Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In Area I
Domestic Air pressure testing in Ibstock, Domestic Air pressure testing in Ilchester, Domestic Air pressure testing in Ilford, Domestic Air pressure testing in Ilfracombe, Domestic Air pressure testing in Ilkeston, Domestic Air pressure testing in Ilkley, Domestic Air pressure testing in Ilminster, Domestic Air pressure testing in Immingham, Domestic Air pressure testing in Ince-in-Makerfield, Domestic Air pressure testing in Ingatestone, Domestic Air pressure testing in Ingleton, Domestic Air pressure testing in Inkberrow, Domestic Air pressure testing in Innerleithen, Domestic Air pressure testing in Insch, Domestic Air pressure testing in Inveraray, Domestic Air pressure testing in Invergordon, Domestic Air pressure testing in Inverkeithing, Domestic Air pressure testing in Inverness, Domestic Air pressure testing in Inverurie, Domestic Air pressure testing in Ipswich, Domestic Air pressure testing in Irchester, Domestic Air pressure testing in Ireland, Domestic Air pressure testing in Irlam, Domestic Air pressure testing in Irthlingborough, Domestic Air pressure testing in Irvine, Domestic Air pressure testing in Isle of Arran, Domestic Air pressure testing in Isle of Scilly, Domestic Air pressure testing in Isle of Skye, Domestic Air pressure testing in Isleworth, Domestic Air pressure testing in Islington, Domestic Air pressure testing in Iver, Domestic Air pressure testing in Ivybridge,