Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
Why E2 Consultants?
E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.
For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.
At E2 Consultants we offer Air Pressure Testing throughout the UK and surrounding areas. Our experienced air pressure testing consultants will also be happy to offer advice on the best ways to gain your target rating.
What Air Permeability Rating Do I Need?
A passing score in the UK is 10 m³/(h.m²) for an air permeability rating which resembles the amount of uncontrolled air that's leaking from the dwelling. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.
How Many Properties Need An Air Tightness Test?
The number of tests required are as follows:
- 4 or less properties of the same type: one test needed per type
- More than 4 but less than 40 dwellings of a type: at least two tests of each type
- More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%
When Should The Test Take Place?
A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.
What Does An Air Leakage Test in the UK Involve?
There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.
Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.
Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Air-Pressure-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
Air Pressure Testing can also be known as:
Domestic Fan Pressure Testing, Domestic Air Integrity Testing, Domestic Air Leakage Testing, Air Integrity Testing, House Leakage Testing, Air Testing, Fan Pressure Testing, Air Tightness Testing, Domestic Air Tightness Testing, Domestic House Leakage Testing, Domestic Air Pressure Testing, Domestic Air Testing, Air Leakage Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In Area I
Domestic Air pressure testing in Ibstock, Domestic Air pressure testing in Ilchester, Domestic Air pressure testing in Ilford, Domestic Air pressure testing in Ilfracombe, Domestic Air pressure testing in Ilkeston, Domestic Air pressure testing in Ilkley, Domestic Air pressure testing in Ilminster, Domestic Air pressure testing in Immingham, Domestic Air pressure testing in Ince-in-Makerfield, Domestic Air pressure testing in Ingatestone, Domestic Air pressure testing in Ingleton, Domestic Air pressure testing in Inkberrow, Domestic Air pressure testing in Innerleithen, Domestic Air pressure testing in Insch, Domestic Air pressure testing in Inveraray, Domestic Air pressure testing in Invergordon, Domestic Air pressure testing in Inverkeithing, Domestic Air pressure testing in Inverness, Domestic Air pressure testing in Inverurie, Domestic Air pressure testing in Ipswich, Domestic Air pressure testing in Irchester, Domestic Air pressure testing in Ireland, Domestic Air pressure testing in Irlam, Domestic Air pressure testing in Irthlingborough, Domestic Air pressure testing in Irvine, Domestic Air pressure testing in Isle of Arran, Domestic Air pressure testing in Isle of Scilly, Domestic Air pressure testing in Isle of Skye, Domestic Air pressure testing in Isleworth, Domestic Air pressure testing in Islington, Domestic Air pressure testing in Iver, Domestic Air pressure testing in Ivybridge,