Offices Nationwide
Environmental Noise Levels
The max exposure time at 85 dBA is 8 hours, at 110 dBA it's just 1 min 29 seconds. If exposed, limit the time and wear hearing protection...more
Air Testing & Leakage
Air Pressure Testing is not just for new-builds, it can be used to find leakage areas in existing buildings, improve the air tightness and improve/stop drafts..more
Part L1B
Conservation of fuel and power in Existing Dwellings
Towcester - SAP Extension Assessment - 0121 381 0129
The office that covers this area is: Birmingham
Phone Number: 0121 381 0129 Email: towcester@e2consultants.co.uk
SAP Extension Calculations is sometimes referred to as SAP Extension Calc, SAP Extension Calculations, SAP Extension Assessment, SAP Extension, SAP Extension Calcs, Part L1B Compliance.
SAP Extension Assessment / SAP Extension Assessment - Towcester
These are a Government defined process in accordance with Part L1B Building Control Regulation Compliance of Domestic Property SAP Extension Assessment are the Government's Standard Assessment Procedure for Energy Rating of Dwellings.
Since 6th April 2006, Part L1B has required SAP Extension Assessment to be carried out on every new conversion.
All SAP Extension Assessment are calculated in accordance with Part L1B of the building regulations.
Many extension designs do not comply with the minimum Part L1b regulations. These require that areas of new glazing account for no more than 25% of new floor area.
We can help you overcome this hurdle easily and quickly.
You will automatically achieve Compliance with Part L1B if the extension envelope is sufficiently insulated, the area of all openings is within the 25% allowance and building service are sufficient. If your dwelling does not achieve this standard our consultants in Towcester will be able to give you advise on how to offset this by potentially upgrading other parts of the dwelling.
The Calculation is produced by creating a Notional and proposed version of the entire dwelling. The notional dwelling is the current building with the extension, this has the known current U Values of the building and the proposed extension defaulted to the L1B 'Upgraded Thermal Elements' standards. This 'Notional' SAP calculation provides a calculated level of annual carbon dioxide emissions which in turn provides a target threshold for the proposed works. The proposed building will be same but with the actual proposed U Values that are going to be used for the new thermal elements and openings. The associated annual carbon dioxide emissions are then compared to the previously calculated target rate.
Conversely, if the proposed extension carbon dioxide emissions are greater than the calculated target threshold, then trade-off improvements will be required to either the extension specification or the existing house as a means offsetting the additional heat loss associated with the extra levels of glazing within the proposed extension above the standard threshold detailed within the Building Regulations
E2 Consultants in Towcester can undertake SAP Calcs to demonstrate compliance with Part L1B (England and Wales) Building Regulations for new build dwellings, extensions and conversions.
At E2 Consultants Towcester we pride ourselves on being able to provide all of the Part L services. Aswell as SAP Extension Assessment we also provide "On Construction" EPCs, Air Tightness/pressureTesting, sound / acoustic testing, A SAP Extension Assessment assessments / BREEAM assessments with consultancy. As part of our service we advise our clients as to how they can best achieve compliance in the most cost effective manner, for this reason all of our SAP Extension Assessment are site specific. Alterations are free of charge and our SAP assessors will also liaise with Building Control Officers on your behalf.
E2 Consultants in Towcester can also provide you with a "On Construction" Energy Performance Certificates (EPCs), they are produced using the SAP methodology and are undertaken by one of our OCDEA (On Construction DEA). The certificates are needed if a property is to be sold or let, they can also be requested by Building Control. Whether E2 Consultants have completed your initial SAP Extension Assessment, your initial SAP assessor is not qualified to produce "On Construction" EPCs or SAP Extension Assessment have not already been carried out on the development, E2 Consultants are able to produce your On Construction Energy Performance Certificates (EPCs).
E2 Consultants in Towcester will try to beat any other price that you might receive. Call one of our regional offices and speak to one of our sap Extension calculation experts on 0121 381 0129 or email towcester@e2consultants.co.uk for a formal quotation.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970