Offices Nationwide

Environmental Noise Levels
The max exposure time at 85 dBA is 8 hours, at 110 dBA it's just 1 min 29 seconds. If exposed, limit the time and wear hearing protection...more

Sound Intensity
Sound intensity's measured in Decibels (dB). An logarithmic scale where an increase of 10 dB gives an apparent doubling of loudness...more
Ripon - Commercial Part E - 01924 578 029
The office that covers this area is: Wakefield
Phone Number: 01924 578 029 Email: ripon@e2consultants.co.uk
Sound Insulation Testing for new or refurbished dwellings
In compliance with Part E of the Building Regulation in Ripon and nationwide, we actively encourage clients to seek our services at the earliest opportunity.
It is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Ripon we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
Our consultants at Ripon can guide you through the process to ensure the best possible chance of achieving sound test passes.
E2 Consultants are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Call 01924 578 029 or email ripon@e2consultants.co.uk to get a quote from one of Ripon consultants..
Pre-Completion Testing - The following table outlines the sets of tests that are required for new and converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Commercial Part E information for your area, be sure to check out Sound-Testing-Wakefield.co.uk.
Our other services include:
Commercial Part E can also be known as:
Commercial Part E Sound Insulation Testing, Part E, Commercial Sound Testing Part E, Part E Sound Insulation Testing, Sound Insulation Design Advice, Commercial Part E Sound Testing, Part E Sound Testing, Part E Testing, Sound Testing Part E, Commercial Part E Testing,


Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970