Offices Nationwide
Air Testing & Leakage
We can offer additional services at discounted rates along side our tests! These are Sound Testing and Part F. Ask our Consultants for more
Air Testing & Leakage
Our engineers use Thermal camera and extensive knowledge of buildings to help find leakage areas within the building and can advice of these.
Thermal Bridging And Airtightness
Enhanced Construction Details
Liversedge - Air tightness testing - 01924 578 029
The office that covers this area is: Wakefield
Phone Number: 01924 578 029 Email: liversedge@e2consultants.co.uk
Air Testing is sometimes referred to as Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness tests, Domestic Air leakage testing, Domestic Air tightness testing, Domestic Air pressure tests.
What Does An Air Leakage Test Involve?
During an air test in Liversedge the pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.
An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results. Please note: an air test cannot be carried out if wind speed is more than 13mph. 3 metres per second is the ideal wind speed when undertaking an air test in Liversedge.
Employees can still do their job inside a commercial building in Liversedge, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building. There should be no outside access once the test has begun - which lasts for approximately 90 minutes, so plan accordingly.
What Air Permeability Rating Do I Need?
Your air permeability rating resembles the amount of uncontrolled air that's leaking from the dwelling. A passing score in Liversedge is 10 m³/(h.m²). If the air test fails, we will help you identify where these leakage areas occur in the hope that a passing rate will be achieved following a re-test.
How Many Properties Need An Air Tightness Test?
The number of tests required are as follows:
- 4 or less properties of the same type: one test needed per type
- More than 4 but less than 40 dwellings of a type: at least two tests of each type
- More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%
When Should The Test Take Place?
A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.
Do I Need An Air Leakage Test?
Part L of the Government building regulations explains that on a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested.
We offer air leakage testing throughout Liversedge where our experienced assessors will be happy to offer advice on the best ways to gain your air permeability rating. Planning your test in advance will help us determine how many tests you'll need ahead of time per property.
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, over a certain size, must have a passing air leakage certificate before the property can be sold.