Offices Nationwide

Environmental Noise Levels
The max exposure time at 85 dBA is 8 hours, at 110 dBA it's just 1 min 29 seconds. If exposed, limit the time and wear hearing protection...more

Sound Transmissions
Paths can be interrupted by insulation and blocking air paths. A material's insulation is governed by mass, stiffening and damping...more
Headcorn - Sound Testing Part E - 020 3390 0301
The office that covers this area is: London
Phone Number: 020 3390 0301 Email: headcorn@e2consultants.co.uk
Sound Insulation Testing for new or refurbished dwellings
In compliance with Part E of the Building Regulation in Headcorn and nationwide, we actively encourage clients to seek our services at the earliest opportunity.
It is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Headcorn we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
E2 Consultants in Headcorn are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Our consultants at Headcorn can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 020 3390 0301 or email headcorn@e2consultants.co.uk
Pre-Completion Testing - The following table outlines the sets of tests that are required for new and converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Sound Testing Part E information for your area, be sure to check out Sound-Testing-London.co.uk.
Our other services include:
Sound Testing Part E can also be known as:
Part E Sound Insulation Testing, Commercial Part E Testing, Part E Testing, Commercial Sound Testing Part E, Sound Insulation Design Advice, Commercial Part E Sound Insulation Testing, Part E Sound Testing, Commercial Part E, Part E, Commercial Part E Sound Testing,


Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970