Offices Nationwide
Point of Reference
10 dBA is the sound level of normal human breathing. To put it into perspective, thunder is a whopping 120 dBA...more
Good Hearing?
A typical person with good hearing can hear from about 20Hz to 20kHz (the audio bandwidth). A person's voice will usually range from 500Hz to 2kHz...more
Hadfield - Commercial Sound Testing Part E - 0114 368 0192
The office that covers this area is: Sheffield
Phone Number: 0114 368 0192 Email: hadfield@e2consultants.co.uk
Commercial_Sound_Testing_Part_E is sometimes referred to as Commercial Part E Compliance, Commercial Sound & Acoustic Insulation Testing, Commercial Acoustic Testing, Commercial Sound Insulation Testing, Commercial Sound Testing.
E2 Consultants delivers Sound Insulation Testing for new or refurbished dwellings in compliance with Part E of the Building Regulation in Hadfield and nationwide.
We actively encourage clients to seek our services at the earliest opportunity as it is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Hadfield we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
Our consultants at Hadfield can guide you through the process to ensure the best possible chance of achieving sound test passes.
E2 Consultants are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Call 0114 368 0192 or email hadfield@e2consultants.co.uk to get a quote from one of Hadfield consultants..
Pre-Completion Testing - The following table outlines the sets of tests required for new and converted properties:
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
For further Commercial Sound Testing Part E information for your area, be sure to check out Sound-Testing-Sheffield.co.uk.
Copyright 2024 E2 Specialist Consultants Limited
Company No. 06728970