Reverberation Time
The reverberation time of a room is defined as the time it takes for sound to decay by 60 dB after an abrupt termination...more

The Decibel Scale
Gives an approx of human perception of loudness. This is because the human ear has a logarithmic response to changes in sound level...more
Part E
Resistance of the Passage of Sound

Middlesex - Commercial Part E - 020 3390 0301
The office that covers this area is: London
The towns & cities that are covered within this county are:
Brentford, Edgeware, Enfield, Feltham, Greenford, Hampton, Harrow, Hayes, Hounslow, Isleworth, Northolt, Norwood, Pinner, Ruislip, Southhall, Stanmore, Sunbury-on-Thames, Teddington, Twickenham, Uxbridge, Wembley, West Drayton,
Phone Number: 020 3390 0301 Email: middlesex@e2consultants.co.uk
Sound Insulation Testing for new or refurbished dwellings
In compliance with Part E of the Building Regulation in Middlesex and nationwide, we actively encourage clients to seek our services at the earliest opportunity.
It is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
As part of our service in Middlesex we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
E2 Consultants in Middlesex are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.
Our consultants at Middlesex can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 020 3390 0301 or email middlesex@e2consultants.co.uk
Pre-Completion Testing - The following table outlines the sets of tests that are required for new and converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows |
Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls |
Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls |
Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes |
To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Commercial Part E information for your area, be sure to check out Sound-Testing-London.co.uk.
Our other services include:
Commercial Part E can also be known as:
Part E Sound Testing, Sound Testing Part E, Commercial Part E Sound Testing, Part E Sound Insulation Testing, Part E Testing, Commercial Sound Testing Part E, Sound Insulation Design Advice, Part E, Commercial Part E Testing, Commercial Part E Sound Insulation Testing,


Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970